Mechanical |
|
Height |
8.75" (22.23 cm) |
|
Width |
4.35" (11.05 cm) |
|
Depth |
16.91" (42.95 cm) |
|
Weight |
10.65 lbs. (4.83 kg) |
|
Units Per Rack |
36 (4 x 9) |
CPU |
|
Type and Speed |
Pentium?4 up to 2.8GHz |
External Bays |
|
3.5" bay |
One low-profile 3.5" bay |
Internal Bays |
|
3.5" bay |
One low-profile 3.5" bay |
I/O |
|
Front I/O |
Power switch, CPU reset button, alarm reset button, status LEDs |
|
Rear I/O |
Five card slots, one DB-25, one DB-9, one PS/2 |
Expansion Slots |
|
Option 1 |
Four 32-bit / 33 MHz PCI (5V) |
|
Option 2 |
One ISA, three 32-bit / 33 MHz PCI (5V) |
|
Option 3 |
Two ISA, two 32-bit / 33 MHz PCI (5V) |
|
Option 4 |
Two ISA, two 64/32-bit / 66/33 MHz PCI (3.3V) |
|
Option 5 |
Three ISA, one 32-bit / 33 MHz PCI (5V) |
Cooling |
|
Fans |
One 17 CFM (0.5m3/min), one 25 CFM (0.7 m3/min) |
Mounting Options |
|
Option 1 |
Front-mount |
|
Option 2 |
Mid-mount |
|
Option 3 |
Base-mount |
|
Option 4 |
Wall-mount |
Power Supply |
|
Option 1 |
100W or 150W 120/240 VAC 50/60 Hz |
|
Option 2 |
130W or 180W 120/240 VAC 50/60 Hz PFC |
|
Option 3 |
100W, 150W or 180W -48 VDC |
Environmental |
|
Operating Temp |
0 to 50 C (32 to 122 F) |
|
Storage Temp |
-40 to 70 C (-40 to 158 F) |
|
Operating Humidity |
5% to 95% (non-condensing) |
|
Storage Altitude |
Up to 10,600 m (34,777 ft) MSL |
|
Operating Altitude |
Up to 4,000 m (13,123 ft) MSL 50 C for 6 hrs |
|
Storage Shock |
20 G |
|
Storage Vibration |
0.5 G @ 5-50 Hz for 30 min, 3.0 G @ 50-500 Hz for 12 min (in shipping carton) |
|
Operating Vibration |
Per Bellcore GR-63-CORE standards: Earthquake - VERTIQll 1.6 G @ 1-50 Hz for 30 sec, Office - 0.1 G @ 1-100 Hz back to 5 Hz for 90 min |
Regulations |
|
Safety |
UL 60950 / CSA C22.2-950 / IEC 60950 |
|
Emissions |
FCC Part 15, Subpart B, ICES-003 (Canada), EN 55022 / CISPR 22, IEC 61000-3-2 - Harmonics, IEC 61000-3-3 - Flicker |
|
Immunity |
EN 55024 / CISPR 24, IEC 61000-4-2 - ESD, IEC -61000-4-3 Radiated RF, IEC 61000-4-4 - EFT, IEC 61000-4-5 - Surge, IEC 61000-4-6 - RF Conducted, IEC 61000-4-11 - Voltage dips, interrupts & varations |
|
Certifications |
UL, C-UL, CE (100 & 150 WAC PS is not CE), FCC, ICES-003 (Canada) |
Additional Regulations |
|
NEBS |
Specific configurations of this chassis have been NEBS Level 3 certified. |
Military Standards |
|
MIL-STD Testing |
Specific configurations of this chassis have been through MIL-STD testing. |
|
MIL-STD-810F |
Method 500.4 Low Pressure (altitude) 15000 ft, Method 501.4 High Temperature-Operating 50 C, Method 502.4 Low Temperature-Operating 0 C, Method 507.4 Humidity-Operating 75%, Method 514.5 Random Vibrating Fig. 514.5C-15 Random, Vibration for shipboard use-Operating, Sinusoidal Vibration for surface ship environment-Operating |
|
MIL-STD-167-1 |
Sinusoidal Vibration for surface ship environment-Operating |
|